Skip to main content.
home | support | download

Back to List Archive

specifying sort causes all ranks to be 1000

From: Fred Toth <ftoth(at)not-real.synernet.com>
Date: Thu Feb 28 2002 - 20:03:33 GMT
Hi all,

I think I've just hit a bug. If I specify a sort option (-s), the sort works
just fine, except that all the ranks come out as 1000. It doesn't matter
what I sort on. Any sort causes the problem.

I'm using build swish-e-2.1-dev-25-2002-02-21.tar.gz.

Here are some examples:

$ swish-e -w html=tibia
# SWISH format: 2.1-dev-25
# Search words: html=tibia
# Number of hits: 23
# Search time: 0.000 seconds
# Run time: 0.040 seconds
1000 bio1999/data/pdfs/a0062237.pdf "The Influence of Different Loading 
Modes on Load-Induced Fluid Displacements in the Rat Tibia" 33440
981 bio1999/data/pdfs/a0014342.pdf "Comparisn Of Soccer Shin Guards In 
Preventing Tibia Fracture" 13175
879 bio1999/data/pdfs/a0127214.pdf "Local Bone Formation In The Rat Tibia 
Due To Mechanical Bending And Intermittent PTH Injection" 21988
466 bio1999/data/pdfs/a0200012.pdf "Adaptation Of Physical Stress In Bone 
Cortical Defect Healing" 9876
466 bio1999/data/pdfs/a0161738.pdf "The Correlation Between The 
Displacement Workspace Of The Human Knee And Anterior Cruciate Ligament 
Disruption Diagnostic Tests" 22571
etc.....

Now with a sort:

$ swish-e -w html=tibia -s swishtitle
# SWISH format: 2.1-dev-25
# Search words: html=tibia
# Number of hits: 23
# Search time: 0.000 seconds
# Run time: 0.040 seconds
1000 bio1999/data/pdfs/a0126036.pdf "3D In Vivo Kinematic Profiles In The 
ACL Deficient Knee Using Cine-Phase Contrast MRI" 31968
1000 bio1999/data/pdfs/a0042950.pdf "A Method For Measuring The Mechanical 
Properties Of Snowboard Boot And Binding Systems In Bending" 48004
1000 bio1999/data/pdfs/a0200012.pdf "Adaptation Of Physical Stress In Bone 
Cortical Defect Healing" 9876
1000 bio1999/data/pdfs/a0010738.pdf "Anisotropic Elastic Properties Of 
Cancellous Bone From A Human Edentulous Mandible" 18451
1000 bio1999/data/pdfs/a0106402.pdf "Axially Compressive Impacts To The 
Human Tibiofemoral Joint" 31323
1000 bio1999/data/pdfs/a0142408.pdf "Biomechanical Considerations For 
Autologous Osteochondral Grafting Of The Femoral Articular Surface" 30213
1000 bio1999/data/pdfs/a0007223.pdf "Biomechanical Response Of Bone To 
Activity Change From Running To Sedentary State In The Rat" 80676
1000 bio1999/data/pdfs/a0014342.pdf "Comparisn Of Soccer Shin Guards In 
Preventing Tibia Fracture" 13175
etc...

Thanks,

Fred
Received on Thu Feb 28 20:04:12 2002